37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 392302 |
Time | |
Date | 199801 |
Day | Fri |
Local Time Of Day | 1201 To 1800 |
Place | |
Locale Reference | atc facility : lga |
State Reference | NY |
Altitude | msl bound lower : 16000 msl bound upper : 19000 |
Environment | |
Light | Daylight |
Aircraft 1 | |
Controlling Facilities | artcc : zny |
Operator | common carrier : air carrier |
Make Model Name | A300 |
Operating Under FAR Part | Part 121 |
Navigation In Use | Other Other |
Flight Phase | descent other |
Route In Use | arrival other arrival star : star enroute airway : zny |
Flight Plan | IFR |
Person 1 | |
Affiliation | company : air carrier |
Function | flight crew : captain oversight : pic |
Qualification | pilot : atp |
ASRS Report | 392302 |
Person 2 | |
Affiliation | company : air carrier |
Function | flight crew : first officer |
Qualification | pilot : atp |
Events | |
Anomaly | aircraft equipment problem : critical other anomaly other |
Independent Detector | aircraft equipment other aircraft equipment : unspecified other flight crewa |
Resolutory Action | none taken : unable |
Consequence | Other |
Supplementary | |
Primary Problem | Aircraft |
Air Traffic Incident | other |
Narrative:
Aircraft was on a ferry flight from tul to jfk. At lendy intersection, was given a descent from FL190 to 16000 ft. As descent was begun, #1 generator faulted and #2 generator picked up AC bus #1 and all electrical busses were pwred normally. The APU was started and it picked up the load on AC bus #1. However, when #1 generator switched was cycled from off back to on, #1 generator faulted again and the APU dropped off the line pwring AC bus #1. After this, selected override supp #2 on and landed without any further electrical problems.
Original NASA ASRS Text
Title: A300 ACFT HAD GENERATOR #1 FAULT, #2 GENERATOR PICKED UP AC BUS #1, APU STARTED AND IT PICKED UP THE #1 AC BUS. GENERATOR #1 WAS CYCLED OFF AND ON AND WHEN THAT WAS DONE, #1 GENERATOR FAULTED AGAIN AND THE APU DROPPED OFF THE LINE. OVERRIDE SUPP #2 WAS SELECTED AND FLT LANDED WITH NO FURTHER ELECTRICAL PROB.
Narrative: ACFT WAS ON A FERRY FLT FROM TUL TO JFK. AT LENDY INTXN, WAS GIVEN A DSCNT FROM FL190 TO 16000 FT. AS DSCNT WAS BEGUN, #1 GENERATOR FAULTED AND #2 GENERATOR PICKED UP AC BUS #1 AND ALL ELECTRICAL BUSSES WERE PWRED NORMALLY. THE APU WAS STARTED AND IT PICKED UP THE LOAD ON AC BUS #1. HOWEVER, WHEN #1 GENERATOR SWITCHED WAS CYCLED FROM OFF BACK TO ON, #1 GENERATOR FAULTED AGAIN AND THE APU DROPPED OFF THE LINE PWRING AC BUS #1. AFTER THIS, SELECTED OVERRIDE SUPP #2 ON AND LANDED WITHOUT ANY FURTHER ELECTRICAL PROBS.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.