Narrative:

On mar/sun/02 aircraft XXX depressurized in-flight and masks deployed. Psu at row 1D and F deployed but were not attached to manifold. Psu at row 18 did not fully deploy and had to be opened by flight attendant. On or around feb/thu/01 I performed check of passenger oxygen system/mask/oxygen generator at rows 10 thru 16 in accordance with job card. All psu's operated properly at that time and detailed inspection of rows 10 thru 16 checked satisfactory.

Google
 

Original NASA ASRS Text

Title: A B737-300 DEPRESSURIZED INFLT AND 3 PAX EMER OXYGEN MASKS WERE FOUND NOT USABLE DUE TO IMPROPER MAINT.

Narrative: ON MAR/SUN/02 ACFT XXX DEPRESSURIZED INFLT AND MASKS DEPLOYED. PSU AT ROW 1D AND F DEPLOYED BUT WERE NOT ATTACHED TO MANIFOLD. PSU AT ROW 18 DID NOT FULLY DEPLOY AND HAD TO BE OPENED BY FLT ATTENDANT. ON OR AROUND FEB/THU/01 I PERFORMED CHK OF PAX OXYGEN SYS/MASK/OXYGEN GENERATOR AT ROWS 10 THRU 16 IN ACCORDANCE WITH JOB CARD. ALL PSU'S OPERATED PROPERLY AT THAT TIME AND DETAILED INSPECTION OF ROWS 10 THRU 16 CHKED SATISFACTORY.

Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.