37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 687117 |
Time | |
Date | 200601 |
Local Time Of Day | 1201 To 1800 |
Place | |
Locale Reference | airport : zzz.airport |
State Reference | US |
Altitude | agl single value : 0 |
Aircraft 1 | |
Operator | common carrier : air carrier |
Make Model Name | EMB ERJ 145 ER&LR |
Operating Under FAR Part | Part 121 |
Flight Phase | ground : maintenance |
Person 1 | |
Affiliation | company : air carrier |
Function | maintenance : technician |
ASRS Report | 687117 |
Person 2 | |
Affiliation | company : air carrier |
Function | maintenance : technician |
Events | |
Anomaly | aircraft equipment problem : critical maintenance problem : improper maintenance maintenance problem : improper documentation maintenance problem : non compliance with mel non adherence : published procedure non adherence : far |
Resolutory Action | none taken : detected after the fact |
Consequence | other |
Factors | |
Maintenance | performance deficiency : non compliance with legal requirements performance deficiency : testing performance deficiency : inspection |
Supplementary | |
Problem Areas | Aircraft Maintenance Human Performance |
Primary Problem | Maintenance Human Performance |
Narrative:
Aircraft had a loud squeal from the service door. Pressurization was deferred in automatic and manual mode per MEL. MEL requires both outflow valves to be secured open with opening tool. Maintenance resealed rubber door trim and lower service kick plate in accordance with 52-00-04-300-801-a; with a notation that the MEL item was restored. Aircraft left and was unable to pressurize aircraft in automatic or manual mode. Upon further investigation it was determined that the outflow opening tool was not removed from the outflow valves. MEL was not restored properly and an operations check of the system and the noise from the door was not performed.
Original NASA ASRS Text
Title: AN EMB145 WITH PRESSURIZATION INOP IN MANUAL AND AUTO DEFERRED AS INOP. CORRECTED PRESSURE LEAK AT SVC DOOR. DISPATCHED ACFT WITH OUTFLOW VALVE LOCKED OPEN.
Narrative: ACFT HAD A LOUD SQUEAL FROM THE SVC DOOR. PRESSURIZATION WAS DEFERRED IN AUTO AND MANUAL MODE PER MEL. MEL REQUIRES BOTH OUTFLOW VALVES TO BE SECURED OPEN WITH OPENING TOOL. MAINT RESEALED RUBBER DOOR TRIM AND LOWER SVC KICK PLATE IN ACCORDANCE WITH 52-00-04-300-801-A; WITH A NOTATION THAT THE MEL ITEM WAS RESTORED. ACFT LEFT AND WAS UNABLE TO PRESSURIZE ACFT IN AUTO OR MANUAL MODE. UPON FURTHER INVESTIGATION IT WAS DETERMINED THAT THE OUTFLOW OPENING TOOL WAS NOT REMOVED FROM THE OUTFLOW VALVES. MEL WAS NOT RESTORED PROPERLY AND AN OPS CHK OF THE SYS AND THE NOISE FROM THE DOOR WAS NOT PERFORMED.