Narrative:

I removed and replaced the digital controller for a MEL to correct an automatic mode problem for the pressurization system. I connected the epov (electro pneumatic outflow valve) vacuum line tube; and ensured no safety wire was still installed to the epov for the existing MEL. The cannon plug was secured also before I had the pressurization adjustment/test performed. The pressurization worked in automatic and manual mode as I stated in the maintenance logbook. Therefore; I was very surprised to come back to work and hear about this incident. But I know that I connected this vacuum line tube to run my pressurization test.

Google
 

Original NASA ASRS Text

Title: AN EMB140 RETURNED TO THE DEP ARPT DUE TO UNABLE TO PRESSURIZE. FOUND VACUUM HOSE NOT CONNECTED TO DIGITAL PRESSURIZATION CTLR.

Narrative: I REMOVED AND REPLACED THE DIGITAL CTLR FOR A MEL TO CORRECT AN AUTO MODE PROB FOR THE PRESSURIZATION SYS. I CONNECTED THE EPOV (ELECTRO PNEUMATIC OUTFLOW VALVE) VACUUM LINE TUBE; AND ENSURED NO SAFETY WIRE WAS STILL INSTALLED TO THE EPOV FOR THE EXISTING MEL. THE CANNON PLUG WAS SECURED ALSO BEFORE I HAD THE PRESSURIZATION ADJUSTMENT/TEST PERFORMED. THE PRESSURIZATION WORKED IN AUTO AND MANUAL MODE AS I STATED IN THE MAINT LOGBOOK. THEREFORE; I WAS VERY SURPRISED TO COME BACK TO WORK AND HEAR ABOUT THIS INCIDENT. BUT I KNOW THAT I CONNECTED THIS VACUUM LINE TUBE TO RUN MY PRESSURIZATION TEST.