Narrative:

Aircraft arrived in ZZZ at approximately XA00 and was scheduled for a maintenance check. While performing check; the crew notified me they had a write-up regarding stall warning 2 would not test. The check was completed and I deferred the #2 stall warning in accordance with MEL procedure 27-3. MEL calls out to pull circuit breaker's stall warning and heater and stall transducer heater for the affected side. I pulled and collared stall transducer and heater #1 instead of #2. Aircraft returned to field and we corrected the problem. I did not pay attention to detail. #1 and #2 stall transducer heater #1 and #2 are on same row on aircraft circuit breaker panel and I pulled the wrong one.

Google
 

Original NASA ASRS Text

Title: MECHANIC WORKING A DHC-8-200 #2 STALL WARNING WOULD NOT TEST WRITE-UP; INADVERTENTLY PULLED AND COLLARED THE #1 STALL WARNING TRANSDUCER AND HEATER. AIRCRAFT RETURNED TO FIELD AND #2 STALL WARNING AND HEATER MEL COMPLIED WITH.

Narrative: ACFT ARRIVED IN ZZZ AT APPROX XA00 AND WAS SCHEDULED FOR A MAINT CHK. WHILE PERFORMING CHK; THE CREW NOTIFIED ME THEY HAD A WRITE-UP REGARDING STALL WARNING 2 WOULD NOT TEST. THE CHK WAS COMPLETED AND I DEFERRED THE #2 STALL WARNING IN ACCORDANCE WITH MEL PROC 27-3. MEL CALLS OUT TO PULL CIRCUIT BREAKER'S STALL WARNING AND HEATER AND STALL TRANSDUCER HEATER FOR THE AFFECTED SIDE. I PULLED AND COLLARED STALL TRANSDUCER AND HEATER #1 INSTEAD OF #2. ACFT RETURNED TO FIELD AND WE CORRECTED THE PROB. I DID NOT PAY ATTN TO DETAIL. #1 AND #2 STALL TRANSDUCER HEATER #1 AND #2 ARE ON SAME ROW ON ACFT CIRCUIT BREAKER PANEL AND I PULLED THE WRONG ONE.

Data retrieved from NASA's ASRS site as of May 2009 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.