Narrative:

I was on IFR at 25000 ft on AR7 when I lost the left generator then right generator. I couldn't get them back on line. I ran on battery and landed at new hanover international. Mechanic worked on the generator connections and with a gpu start, generators came on line. No further problem continued flight to bos area. I was flying a twin small transport.

Google
 

Original NASA ASRS Text

Title: AN SMT LOSES PRIMARY ELECTRICAL PWR AND DIVERTS FOR A PRECAUTIONARY LNDG AT AN ALT ARPT.

Narrative: I WAS ON IFR AT 25000 FT ON AR7 WHEN I LOST THE L GENERATOR THEN R GENERATOR. I COULDN'T GET THEM BACK ON LINE. I RAN ON BATTERY AND LANDED AT NEW HANOVER INTL. MECH WORKED ON THE GENERATOR CONNECTIONS AND WITH A GPU START, GENERATORS CAME ON LINE. NO FURTHER PROBLEM CONTINUED FLT TO BOS AREA. I WAS FLYING A TWIN SMT.

Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.