37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 291492 |
Time | |
Date | 199412 |
Day | Mon |
Local Time Of Day | 0001 To 0600 |
Place | |
Locale Reference | atc facility : cvg |
State Reference | OH |
Altitude | msl bound lower : 23000 msl bound upper : 23000 |
Environment | |
Flight Conditions | VMC |
Light | Night |
Aircraft 1 | |
Controlling Facilities | artcc : zid |
Operator | common carrier : air carrier |
Make Model Name | Brasilia EMB-120 All Series |
Operating Under FAR Part | Part 135 |
Flight Phase | cruise other |
Flight Plan | IFR |
Person 1 | |
Affiliation | company : air carrier |
Function | flight crew : captain oversight : pic |
Qualification | pilot : commercial pilot : instrument pilot : atp |
Experience | flight time last 90 days : 191 flight time total : 12500 flight time type : 2211 |
ASRS Report | 291492 |
Person 2 | |
Affiliation | company : air carrier |
Function | flight crew : first officer |
Qualification | pilot : commercial pilot : instrument |
Events | |
Anomaly | aircraft equipment problem : critical other anomaly other |
Independent Detector | aircraft equipment other aircraft equipment : unspecified other flight crewa |
Resolutory Action | flight crew : declared emergency none taken : anomaly accepted |
Consequence | faa : investigated Other |
Supplementary | |
Primary Problem | Aircraft |
Air Traffic Incident | other |
Narrative:
On a ferry flight from M39 to cvg at FL230 in clear air, the left engine quit. The electronic engine control went to manual from takeoff (normal position). All engine instruments indicated a flameout condition. The engine was secured using the precautionary engine shutdown procedure. WX at intermediate airports was below or at minimums. We continued to cvg and landed with no further problems.
Original NASA ASRS Text
Title: DURING A FERRY FLT, 1 ENG ELECTRONIC CTL UNIT MALFUNCTIONED RESULTING IN THE FLC MAKING A PRECAUTIONARY ENG SHUTDOWN.
Narrative: ON A FERRY FLT FROM M39 TO CVG AT FL230 IN CLR AIR, THE L ENG QUIT. THE ELECTRONIC ENG CTL WENT TO MANUAL FROM TKOF (NORMAL POS). ALL ENG INSTS INDICATED A FLAMEOUT CONDITION. THE ENG WAS SECURED USING THE PRECAUTIONARY ENG SHUTDOWN PROC. WX AT INTERMEDIATE ARPTS WAS BELOW OR AT MINIMUMS. WE CONTINUED TO CVG AND LANDED WITH NO FURTHER PROBS.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.