Narrative:

WX in clouds. Thunderstorms in area. Uncontrollable cabin climb at FL330. Air-conditioning packs normal. Outflow valve closed. Flow light on. Performed operating manual procedures. No help. Made emergency descent using checklist procedures. Per bulletins and discussion with tulsa technician this appears to be a recurring MD80 super problem. Crews need more information, especially concerning the procedure of turning the packs warmer in order to unfreeze the water separator.

Google
 

Original NASA ASRS Text

Title: MD80 SUPER ANTI-ICE ALL ON AT FL330 FLC UNABLE TO MAINTAIN CABIN PRESSURIZATION, EXECUTES AN EMER DSCNT.

Narrative: WX IN CLOUDS. TSTMS IN AREA. UNCTLABLE CABIN CLB AT FL330. AIR-CONDITIONING PACKS NORMAL. OUTFLOW VALVE CLOSED. FLOW LIGHT ON. PERFORMED OPERATING MANUAL PROCS. NO HELP. MADE EMER DSCNT USING CHKLIST PROCS. PER BULLETINS AND DISCUSSION WITH TULSA TECHNICIAN THIS APPEARS TO BE A RECURRING MD80 SUPER PROB. CREWS NEED MORE INFO, ESPECIALLY CONCERNING THE PROC OF TURNING THE PACKS WARMER IN ORDER TO UNFREEZE THE WATER SEPARATOR.