37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 450255 |
Time | |
Date | 199909 |
Day | Thu |
Local Time Of Day | 1801 To 2400 |
Place | |
Locale Reference | airport : zzz.airport |
State Reference | US |
Altitude | agl single value : 0 |
Environment | |
Light | Night |
Aircraft 1 | |
Operator | common carrier : air carrier |
Make Model Name | MD-80 Super 80 |
Operating Under FAR Part | Part 121 |
Flight Phase | ground : parked ground : maintenance |
Flight Plan | IFR |
Person 1 | |
Affiliation | company : air carrier |
Function | maintenance : technician |
Qualification | technician : airframe technician : powerplant |
ASRS Report | 450255 |
Person 2 | |
Affiliation | company : air carrier |
Function | oversight : supervisor |
Qualification | technician : powerplant technician : airframe |
Events | |
Anomaly | aircraft equipment problem : critical maintenance problem : improper maintenance non adherence : published procedure |
Resolutory Action | none taken : unable |
Consequence | other other |
Factors | |
Maintenance | contributing factor : schedule pressure performance deficiency : inspection performance deficiency : installation performance deficiency : non compliance with legal requirements |
Supplementary | |
Problem Areas | Aircraft Maintenance Human Performance |
Primary Problem | Maintenance Human Performance |
Narrative:
I replaced #1 and #2 cabin pressurization controllers. I accomplished the bite checks for both controllers but I forgot that I had to accomplish a static leak check. I notified abc wzxx gf ZZZ aft line at XD45 so he could notify maintenance technician to schedule a static check. This event occurred shortly after aircraft departed ZZZ.
Original NASA ASRS Text
Title: AN MD SUPER 80 WAS DISPATCHED AND OPERATED IN NON COMPLIANCE WITH #1 AND #2 PRESSURE CONTROLLERS REPLACED AND REQUIRED PITOT STATIC NOT ACCOMPLISHED.
Narrative: I REPLACED #1 AND #2 CABIN PRESSURIZATION CONTROLLERS. I ACCOMPLISHED THE BITE CHKS FOR BOTH CONTROLLERS BUT I FORGOT THAT I HAD TO ACCOMPLISH A STATIC LEAK CHK. I NOTIFIED ABC WZXX GF ZZZ AFT LINE AT XD45 SO HE COULD NOTIFY MAINT TECHNICIAN TO SCHEDULE A STATIC CHK. THIS EVENT OCCURRED SHORTLY AFTER ACFT DEPARTED ZZZ.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.