37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 485400 |
Time | |
Date | 200009 |
Day | Fri |
Local Time Of Day | 0601 To 1200 |
Place | |
Locale Reference | airport : cvg.airport |
State Reference | KY |
Altitude | agl single value : 0 |
Environment | |
Flight Conditions | VMC |
Light | Daylight |
Aircraft 1 | |
Controlling Facilities | tower : cvg.tower |
Operator | common carrier : air carrier |
Make Model Name | Regional Jet CL65, Undifferentiated or Other Model |
Operating Under FAR Part | Part 121 |
Flight Phase | ground : takeoff roll |
Flight Plan | IFR |
Person 1 | |
Affiliation | company : air carrier |
Function | flight crew : captain oversight : pic |
Qualification | pilot : atp |
Experience | flight time last 90 days : 250 flight time total : 10000 flight time type : 200 |
ASRS Report | 485400 |
Person 2 | |
Affiliation | company : air carrier |
Function | flight crew : first officer |
Qualification | pilot : commercial pilot : instrument pilot : multi engine |
Events | |
Anomaly | aircraft equipment problem : critical other anomaly other |
Independent Detector | aircraft equipment other aircraft equipment : stall fail warning other flight crewa |
Resolutory Action | flight crew : rejected takeoff |
Consequence | other |
Supplementary | |
Problem Areas | Aircraft Flight Crew Human Performance |
Primary Problem | Aircraft |
Narrative:
The takeoff was aborted for a 'stall fail' caution message. Flight returned to the gate for maintenance. Callback conversation with reporter revealed the following information: the reporter stated the aircraft was a canadair CL65 and the exact component failure is unknown. The reporter said when the aircraft returned to the gate the crew was assigned to another aircraft and departed before maintenance repaired the stall warning system.
Original NASA ASRS Text
Title: A CANADAIR CL65 ON TKOF ROLL REJECTED THE TKOF DUE TO A STALL FAIL CAUTION MESSAGE, CAUSE UNKNOWN.
Narrative: THE TKOF WAS ABORTED FOR A 'STALL FAIL' CAUTION MESSAGE. FLT RETURNED TO THE GATE FOR MAINT. CALLBACK CONVERSATION WITH RPTR REVEALED THE FOLLOWING INFO: THE RPTR STATED THE ACFT WAS A CANADAIR CL65 AND THE EXACT COMPONENT FAILURE IS UNKNOWN. THE RPTR SAID WHEN THE ACFT RETURNED TO THE GATE THE CREW WAS ASSIGNED TO ANOTHER ACFT AND DEPARTED BEFORE MAINT REPAIRED THE STALL WARNING SYS.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.