37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 539161 |
Time | |
Date | 200202 |
Day | Mon |
Local Time Of Day | 1201 To 1800 |
Place | |
Locale Reference | airport : dfw.airport |
State Reference | TX |
Altitude | agl single value : 0 |
Environment | |
Light | Daylight |
Aircraft 1 | |
Operator | common carrier : air carrier |
Operating Under FAR Part | Part 121 |
Flight Phase | ground : taxi |
Flight Plan | IFR |
Person 1 | |
Affiliation | company : air carrier |
Function | flight crew : captain oversight : pic |
Qualification | pilot : atp |
ASRS Report | 539161 |
Person 2 | |
Affiliation | company : air carrier |
Function | flight crew : first officer |
Qualification | pilot : atp |
ASRS Report | 539163 |
Events | |
Anomaly | aircraft equipment problem : less severe maintenance problem : non compliance with mel maintenance problem : improper documentation non adherence : far non adherence : published procedure non adherence : company policies other anomaly other |
Independent Detector | aircraft equipment other aircraft equipment : eicas other flight crewa other flight crewb |
Resolutory Action | none taken : detected after the fact other |
Consequence | other other |
Factors | |
Maintenance | contributing factor : schedule pressure performance deficiency : repair performance deficiency : non compliance with legal requirements |
Supplementary | |
Problem Areas | Company Aircraft Maintenance Human Performance |
Primary Problem | Maintenance Human Performance |
Narrative:
MEL compliance. After gate departure, right high pressure pneumatic bleed valve would not open. Tried to troubleshoot while returning to the gate. Maintenance could not fix and placarded right high pressure shutoff valve inoperative per MEL xx-XXX. After they left, we called them back to placard additional item related to that MEL item. There was an additional MEL provision all involved overlooked. Found out about said item en route to lax. Had the hydraulic driven generator placarded in lax. Hydraulic driven generator not required on domestic operation, however, it did not comply to the letter of MEL.
Original NASA ASRS Text
Title: B767 CREW FOUND MAINT DID NOT PLACARD ALL REQUIRED ITEMS CALLED FOR IN MEL DEFERRAL OF A PNEUMATIC HIGH PRESSURE BLEED VALVE THAT WOULD NOT OPEN.
Narrative: MEL COMPLIANCE. AFTER GATE DEP, R HIGH PRESSURE PNEUMATIC BLEED VALVE WOULD NOT OPEN. TRIED TO TROUBLESHOOT WHILE RETURNING TO THE GATE. MAINT COULD NOT FIX AND PLACARDED R HIGH PRESSURE SHUTOFF VALVE INOP PER MEL XX-XXX. AFTER THEY LEFT, WE CALLED THEM BACK TO PLACARD ADDITIONAL ITEM RELATED TO THAT MEL ITEM. THERE WAS AN ADDITIONAL MEL PROVISION ALL INVOLVED OVERLOOKED. FOUND OUT ABOUT SAID ITEM ENRTE TO LAX. HAD THE HYD DRIVEN GENERATOR PLACARDED IN LAX. HYD DRIVEN GENERATOR NOT REQUIRED ON DOMESTIC OP, HOWEVER, IT DID NOT COMPLY TO THE LETTER OF MEL.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.