37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 701513 |
Time | |
Date | 200606 |
Local Time Of Day | 1201 To 1800 |
Place | |
Locale Reference | airport : zzz.airport |
State Reference | US |
Altitude | agl single value : 0 |
Aircraft 1 | |
Operator | common carrier : air carrier |
Make Model Name | SF 340A |
Operating Under FAR Part | Part 121 |
Flight Phase | ground : maintenance |
Person 1 | |
Affiliation | company : air carrier |
Function | maintenance : technician |
ASRS Report | 701513 |
Person 2 | |
Affiliation | company : air carrier |
Function | maintenance : lead technician |
Events | |
Anomaly | aircraft equipment problem : critical maintenance problem : improper maintenance maintenance problem : improper documentation non adherence : published procedure non adherence : far |
Independent Detector | other other : 1 |
Resolutory Action | none taken : detected after the fact |
Consequence | other |
Factors | |
Maintenance | contributing factor : work cards performance deficiency : non compliance with legal requirements performance deficiency : scheduled maintenance performance deficiency : inspection |
Supplementary | |
Problem Areas | Chart Or Publication Maintenance Human Performance Aircraft |
Primary Problem | Chart Or Publication |
Narrative:
I was notified that personal breathing equipment part number and serial number had an incorrect 'a' code based on its date of manufacture. System showed A17 (10 yr discard) but it should have been A1322 (5 yr discard). Based on a manufacture date of dec/2000; this personal breathing equipment should have been discarded in dec/2005. After confirming this information; I discussed the problem and submitted a special request to planning department to have the personal breathing equipment replaced. The special request was entered by planning.
Original NASA ASRS Text
Title: AN SF340 WAS RPTED TO HAVE A PERSONAL BREATHING KIT THAT WAS OUT OF TIME. SPECIAL WORK REQUEST ENTERED TO REPLACE AT FIRST MAINT STATION.
Narrative: I WAS NOTIFIED THAT PERSONAL BREATHING EQUIP PART NUMBER AND SERIAL NUMBER HAD AN INCORRECT 'A' CODE BASED ON ITS DATE OF MANUFACTURE. SYS SHOWED A17 (10 YR DISCARD) BUT IT SHOULD HAVE BEEN A1322 (5 YR DISCARD). BASED ON A MANUFACTURE DATE OF DEC/2000; THIS PERSONAL BREATHING EQUIP SHOULD HAVE BEEN DISCARDED IN DEC/2005. AFTER CONFIRMING THIS INFO; I DISCUSSED THE PROB AND SUBMITTED A SPECIAL REQUEST TO PLANNING DEPT TO HAVE THE PERSONAL BREATHING EQUIP REPLACED. THE SPECIAL REQUEST WAS ENTERED BY PLANNING.
Data retrieved from NASA's ASRS site as of January 2009 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.