Aircraft 1 | |
Make Model Name | EMB ERJ 145 ER&LR |
Operating Under FAR Part | Part 121 |
Flight Phase | Parked Taxi |
Component | |
Aircraft Component | Engine Air Pneumatic Ducting |
Person 1 | |
Function | Technician |
Qualification | Maintenance Airframe Maintenance Powerplant |
Events | |
Anomaly | Aircraft Equipment Problem Critical Flight Deck / Cabin / Aircraft Event Smoke / Fire / Fumes / Odor |
Narrative:
During maintenance testing; while taxiing an emb-145 aircraft; the cabin filled with smoke at ZZZ airport.caps were not removed before installing v-clamps; in accordance with (in accordance with) emb-145 amm 36-11-04 part I; step 7.maintenance complied with an engineering order (eo) chapter 36-00-04 for the bleed servo line restrictor and damper removal & cleaning. Operational checks good.emb-145 amm reference 36-11-04; is not accurate in the procedures for installation. Pre -cooler must be placed in pylon with ducts in order to install. Pre-cooler can not be pre-assembled before installation.
Original NASA ASRS Text
Title: A Line Mechanic reports an EMB/ERJ-145 cabin filled with smoke during maintenance testing and taxiing after a pre-cooler was replaced. Protective end caps had not been removed from the Pre-cooler prior to connecting pneumatic ducts to the Pre-cooler; during installation in the engine pylon.
Narrative: During maintenance testing; while taxiing an EMB-145 aircraft; the cabin filled with smoke at ZZZ Airport.Caps were not removed before installing V-Clamps; in accordance with (IAW) EMB-145 AMM 36-11-04 Part I; Step 7.Maintenance complied with an Engineering Order (EO) Chapter 36-00-04 for the Bleed Servo line restrictor and damper removal & cleaning. Operational checks good.EMB-145 AMM Reference 36-11-04; is not accurate in the procedures for installation. Pre -cooler must be placed in pylon with ducts in order to install. Pre-cooler can not be pre-assembled before installation.