Narrative:

After departing pit, the left oil strainer clogging light illuminated! We completed the appropriate abnormal checklist which led us to a precautionary engine shutdown. An emergency was declared and we returned to pit. Total flight time was approximately 15 min with single engine time of approximately 5 min. Upon reading the gate in pit, the filter was checked for contamination and none was found.

Google
 

Original NASA ASRS Text

Title: ACR MLG'S RETURN LAND MANDATED BY ACFT EQUIP PROB.

Narrative: AFTER DEPARTING PIT, THE L OIL STRAINER CLOGGING LIGHT ILLUMINATED! WE COMPLETED THE APPROPRIATE ABNORMAL CHKLIST WHICH LED US TO A PRECAUTIONARY ENG SHUTDOWN. AN EMER WAS DECLARED AND WE RETURNED TO PIT. TOTAL FLT TIME WAS APPROX 15 MIN WITH SINGLE ENG TIME OF APPROX 5 MIN. UPON READING THE GATE IN PIT, THE FILTER WAS CHKED FOR CONTAMINATION AND NONE WAS FOUND.

Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.