37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 292534 |
Time | |
Date | 199412 |
Day | Fri |
Local Time Of Day | 0601 To 1200 |
Place | |
Locale Reference | airport : dfw |
State Reference | TX |
Altitude | msl bound lower : 5000 msl bound upper : 5000 |
Environment | |
Flight Conditions | VMC |
Light | Daylight |
Aircraft 1 | |
Controlling Facilities | tracon : dfw |
Operator | common carrier : air carrier |
Make Model Name | MD-80 Super 80 |
Operating Under FAR Part | Part 121 |
Navigation In Use | Other Other |
Flight Phase | climbout : intermediate altitude |
Flight Plan | IFR |
Person 1 | |
Affiliation | company : air carrier |
Function | flight crew : captain oversight : pic |
Qualification | pilot : atp |
ASRS Report | 292534 |
Person 2 | |
Affiliation | company : air carrier |
Function | flight crew : first officer |
Qualification | pilot : atp |
ASRS Report | 292535 |
Events | |
Anomaly | aircraft equipment problem : critical non adherence : far non adherence : published procedure |
Independent Detector | aircraft equipment other aircraft equipment : unspecified other flight crewa |
Resolutory Action | flight crew : overcame equipment problem other |
Consequence | Other |
Supplementary | |
Primary Problem | Aircraft |
Air Traffic Incident | Pilot Deviation |
Narrative:
Aircraft had numerous write-ups of oxygen quantity loss. Mechanic replaced B fitting and all tests were normal. Prior to takeoff oxygen quantity checked normal. During climb out first officer's oxygen mask was expelling oxygen. Pressure was decreasing -- turned off oxygen valve on cylinder and loss was stopped. Gross weight was 141.4 with a full passenger load. Decision was made to continue rather than to air interrupt. Briefing was made that in the event of a pressurization problem to turn on oxygen valve and land at nearest suitable. Flight was completed uneventful.
Original NASA ASRS Text
Title: FO'S OXYGEN SYS (CREW) LEAKING. FLC TURNS OFF OXYGEN AT THE BOTTLE AND CONTINUES FLT.
Narrative: ACFT HAD NUMEROUS WRITE-UPS OF OXYGEN QUANTITY LOSS. MECH REPLACED B FITTING AND ALL TESTS WERE NORMAL. PRIOR TO TKOF OXYGEN QUANTITY CHKED NORMAL. DURING CLBOUT FO'S OXYGEN MASK WAS EXPELLING OXYGEN. PRESSURE WAS DECREASING -- TURNED OFF OXYGEN VALVE ON CYLINDER AND LOSS WAS STOPPED. GROSS WT WAS 141.4 WITH A FULL PAX LOAD. DECISION WAS MADE TO CONTINUE RATHER THAN TO AIR INTERRUPT. BRIEFING WAS MADE THAT IN THE EVENT OF A PRESSURIZATION PROB TO TURN ON OXYGEN VALVE AND LAND AT NEAREST SUITABLE. FLT WAS COMPLETED UNEVENTFUL.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.