Narrative:

Departed st louis bound for washington national, dc, at XA19. During climb, lost #2 B pump (later determined to be a crack in the pump casing) indicated by #2 B pump low pressure light. Leveled at FL220 then initiated return to st louis. Prior to landing, lost B system pressure due to fluid loss. Uneventful landing.

Google
 

Original NASA ASRS Text

Title: A B727-200 IN CLB AT FL220 RETURNED TO THE FIELD DUE TO LOSS OF B HYD SYS PRESSURE AND QUANTITY CAUSED BY A CRACKED B PUMP CASE.

Narrative: DEPARTED ST LOUIS BOUND FOR WASHINGTON NATL, DC, AT XA19. DURING CLB, LOST #2 B PUMP (LATER DETERMINED TO BE A CRACK IN THE PUMP CASING) INDICATED BY #2 B PUMP LOW PRESSURE LIGHT. LEVELED AT FL220 THEN INITIATED RETURN TO ST LOUIS. PRIOR TO LNDG, LOST B SYS PRESSURE DUE TO FLUID LOSS. UNEVENTFUL LNDG.

Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.