37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 492218 |
Time | |
Date | 200011 |
Day | Sun |
Local Time Of Day | 1801 To 2400 |
Place | |
Locale Reference | airport : zzz.airport |
State Reference | US |
Altitude | agl single value : 0 |
Environment | |
Light | Night |
Aircraft 1 | |
Operator | common carrier : air carrier |
Make Model Name | MD-88 |
Operating Under FAR Part | Part 121 |
Flight Phase | ground : maintenance ground : parked |
Person 1 | |
Affiliation | company : air carrier |
Function | maintenance : technician |
Qualification | technician : powerplant technician : airframe |
Experience | maintenance technician : 12 |
ASRS Report | 492218 |
Person 2 | |
Affiliation | company : air carrier |
Function | maintenance : lead technician |
Qualification | technician : powerplant technician : airframe |
Events | |
Anomaly | maintenance problem : improper maintenance maintenance problem : improper documentation non adherence : published procedure |
Independent Detector | other other : 1 |
Consequence | other |
Factors | |
Maintenance | contributing factor : work cards contributing factor : engineering procedure |
Supplementary | |
Problem Areas | Maintenance Human Performance Aircraft Chart Or Publication |
Primary Problem | Chart Or Publication |
Narrative:
While performing special inspection engineering order WX-xx-vv generator bus circuit breaker panel wire chafing inspection on aircraft xyz on nov/xa/00, no wire chafing was detected per step F sheet 4 of engineering order WX-xx-vv. Per step G of sheet 4, no chafing protection was applied. Advised air carrier maintenance coordination center of problem. A rework of the special inspection will be set up to accomplish step G of engineering order WX-xx-vv.
Original NASA ASRS Text
Title: AN MD88 DURING AN ENGINEERING ORDER TO INSPECT WIRE BUNDLES BEHIND THE GENERATOR CTL PANELS FOR CHAFING. NONE FOUND, BUT DUE TO CONFUSING INSTRUCTIONS, NO CHAFING PROTECTION WAS INSTALLED.
Narrative: WHILE PERFORMING SPECIAL INSPECTION ENGINEERING ORDER WX-XX-VV GENERATOR BUS CIRCUIT BREAKER PANEL WIRE CHAFING INSPECTION ON ACFT XYZ ON NOV/XA/00, NO WIRE CHAFING WAS DETECTED PER STEP F SHEET 4 OF ENGINEERING ORDER WX-XX-VV. PER STEP G OF SHEET 4, NO CHAFING PROTECTION WAS APPLIED. ADVISED ACR MAINT COORD CTR OF PROB. A REWORK OF THE SPECIAL INSPECTION WILL BE SET UP TO ACCOMPLISH STEP G OF ENGINEERING ORDER WX-XX-VV.