37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 510170 |
Time | |
Date | 200105 |
Day | Fri |
Local Time Of Day | 0601 To 1200 |
Place | |
Locale Reference | atc facility : rno.tracon |
State Reference | NV |
Altitude | msl single value : 10000 |
Environment | |
Flight Conditions | VMC |
Light | Daylight |
Aircraft 1 | |
Operator | general aviation : corporate |
Make Model Name | Falcon 50 |
Flight Phase | climbout : intermediate altitude |
Route In Use | departure sid : reno 2 |
Flight Plan | IFR |
Person 1 | |
Affiliation | company : corporate |
Function | flight crew : first officer |
Qualification | pilot : atp |
Experience | flight time last 90 days : 100 flight time total : 6000 flight time type : 100 |
ASRS Report | 510170 |
Events | |
Anomaly | non adherence : published procedure non adherence : clearance other spatial deviation |
Resolutory Action | controller : issued new clearance controller : issued advisory flight crew : became reoriented flight crew : returned to intended or assigned course |
Consequence | faa : reviewed incident with flight crew |
Supplementary | |
Problem Areas | Flight Crew Human Performance |
Primary Problem | Flight Crew Human Performance |
Air Traffic Incident | Pilot Deviation |
Narrative:
Prepped and flew incorrect SID. Turned at 3 NM down range on rno to the fmg VOR in accordance with the FMG5 departure. When advised by ATC, both crew members acknowledged the error, and turned to rejoin the RENO2 fmg departure as originally cleared. ATC then advised a 120 degree heading and the flight continued as previously cleared. ARTCC supervisor was contacted by phone from aircraft to discuss our mistake. No report was requested at that time.
Original NASA ASRS Text
Title: WRONG SID USED, HDG TRACK DEV BY AN FA50 FLT CREW OUT OF RNO, NV.
Narrative: PREPPED AND FLEW INCORRECT SID. TURNED AT 3 NM DOWN RANGE ON RNO TO THE FMG VOR IN ACCORDANCE WITH THE FMG5 DEP. WHEN ADVISED BY ATC, BOTH CREW MEMBERS ACKNOWLEDGED THE ERROR, AND TURNED TO REJOIN THE RENO2 FMG DEP AS ORIGINALLY CLRED. ATC THEN ADVISED A 120 DEG HDG AND THE FLT CONTINUED AS PREVIOUSLY CLRED. ARTCC SUPVR WAS CONTACTED BY PHONE FROM ACFT TO DISCUSS OUR MISTAKE. NO RPT WAS REQUESTED AT THAT TIME.