Person 1 | |
Affiliation | company : air carrier |
Function | maintenance : technician |
Qualification | technician : powerplant technician : airframe |
ASRS Report | 618894 |
Events | |
Anomaly | aircraft equipment problem : critical maintenance problem : non compliance with mel non adherence : published procedure non adherence : far |
Independent Detector | other other : person 1 gnd |
Resolutory Action | none taken : detected after the fact |
Consequence | other other |
Factors | |
Maintenance | contributing factor : manuals contributing factor : non availability of parts contributing factor : schedule pressure performance deficiency : logbook entry performance deficiency : non compliance with legal requirements |
Supplementary | |
Problem Areas | Aircraft Chart Or Publication Maintenance Human Performance |
Primary Problem | Chart Or Publication |
Situations | |
Publication | Minimum Equipment List |
Narrative:
Deferred automated external defibrillator on aircraft #1 with MEL #25-17. Item not deferrable. Under 25-17 second paragraph, was misunderstood that 1 automated external defibrillator installed and zero required. My thinking was 2 automated external defibrillator's were on aircraft. Automated external defibrillator in nis in ZZZ at the time.618894 syn
Original NASA ASRS Text
Title: A B737-300 WAS DISPATCHED IN NON COMPLIANCE WITH NO AUTOMATED EXTERNAL DEFIBRILLATOR BOARDED. CAUSED BY MEL NOT CURRENT WITH UPDATED REVISIONS.
Narrative: DEFERRED AUTOMATED EXTERNAL DEFIBRILLATOR ON ACFT #1 WITH MEL #25-17. ITEM NOT DEFERRABLE. UNDER 25-17 SECOND PARAGRAPH, WAS MISUNDERSTOOD THAT 1 AUTOMATED EXTERNAL DEFIBRILLATOR INSTALLED AND ZERO REQUIRED. MY THINKING WAS 2 AUTOMATED EXTERNAL DEFIBRILLATOR'S WERE ON ACFT. AUTOMATED EXTERNAL DEFIBRILLATOR IN NIS IN ZZZ AT THE TIME.618894 SYN