Narrative:

Jun/08 I received a horizontal stabilizer trim actuator into the carrier part tracking system. On dec/08 I was informed by chief inspector that the certification paperwork was incorrect. Efforts are ongoing to get the proper certification documents from the vendor. Manufacturer in ZZZ is carrier's approved vendor. However; manufacturer in ZZZ does not do the repair; they send the item to manufacturer in ZZZ! After the repair is done; the item is returned to ZZZ. The item is then sent to the end user. On arrival at ZZZ the item is entered into the system by the receiving clerk. The item is then received the carrier part tracking system by the receiving inspector. I entered the required data into carrier part tracking system using the 8130 issued by manufacturer in ZZZ1. I did not realize that manufacturer was working under 2 addresses. The document issued by manufacturer in ZZZ had the certificate of conformity statement X'ed out and the 'maintenance release issued' checked 'no.' working with the belief that I had a 'valid' 8130; I certified the part and released it for issue. The part was subsequently installed on aircraft X.

Google
 

Original NASA ASRS Text

Title: A Mechanic is informed by his Chief Inspector the certification paperwork was incorrect for the Receiving Inspection documentation on their CRJ-700 Horizontal Stabilizer Trim Actuator (HSTA) from a foreign repair vendor.

Narrative: Jun/08 I received a Horizontal Stabilizer Trim Actuator into the carrier part tracking system. On Dec/08 I was informed by Chief Inspector that the certification paperwork was incorrect. Efforts are ongoing to get the proper certification documents from the vendor. Manufacturer in ZZZ is carrier's approved vendor. However; manufacturer in ZZZ does not do the repair; they send the item to manufacturer in ZZZ! After the repair is done; the item is returned to ZZZ. The item is then sent to the end user. On arrival at ZZZ the item is entered into the system by the receiving clerk. The item is then received the carrier part tracking system by the Receiving Inspector. I entered the required data into carrier part tracking system using the 8130 issued by manufacturer in ZZZ1. I did not realize that manufacturer was working under 2 addresses. The document issued by manufacturer in ZZZ had the certificate of conformity statement X'ed out and the 'Maintenance Release Issued' checked 'No.' Working with the belief that I had a 'Valid' 8130; I certified the part and released it for issue. The part was subsequently installed on Aircraft X.

Data retrieved from NASA's ASRS site as of May 2009 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.