37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 973971 |
Time | |
Date | 201110 |
Local Time Of Day | 0601-1200 |
Place | |
Locale Reference | ZZZ.Airport |
State Reference | US |
Environment | |
Light | Daylight |
Aircraft 1 | |
Make Model Name | Regional Jet 200 ER/LR (CRJ200) |
Operating Under FAR Part | Part 121 |
Flight Phase | Landing |
Component | |
Aircraft Component | Cowling |
Person 1 | |
Function | Technician |
Qualification | Maintenance Airframe Maintenance Powerplant |
Person 2 | |
Function | Technician |
Qualification | Maintenance Powerplant Maintenance Airframe |
Events | |
Anomaly | Aircraft Equipment Problem Critical Deviation - Procedural Published Material / Policy |
Narrative:
Routine overnight maintenance (ron). Cowls removed for maintenance; then re-installed. Number 1 engine lower [cowling] came off on landing. As far as I know; [cowling] reinstalled and returned to service. Suggest following company procedures. Do eddy current checks on cowls that are re-installed.
Original NASA ASRS Text
Title: After performing Routine Overnight Maintenance (RON); including removing and reinstalling engine cowls; a lower cowling departed a CRJ-200 aircraft on landing.
Narrative: Routine Overnight Maintenance (RON). Cowls removed for maintenance; then re-installed. Number 1 Engine lower [cowling] came off on landing. As far as I know; [cowling] reinstalled and returned to service. Suggest following company procedures. Do Eddy Current Checks on cowls that are re-installed.
Data retrieved from NASA's ASRS site as of April 2012 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.