Narrative:

Returned to departure airport due to CSD disconnects on #2 engine. After departure from rdu, #2 and #3 engine CSD rise temperature stayed in the caution range over 3 mins. Disconnected #2 and #3 CSD per operating manual abnormal procedure. Reviewed and executed single generator abnormal procedure. Returned to rdu. Landed normally below maximum landing weight.

Google
 

Original NASA ASRS Text

Title: ACFT HAD TO RETURN LAND WHEN 2 CSD'S WERE SHUT DOWN.

Narrative: RETURNED TO DEP ARPT DUE TO CSD DISCONNECTS ON #2 ENG. AFTER DEP FROM RDU, #2 AND #3 ENG CSD RISE TEMP STAYED IN THE CAUTION RANGE OVER 3 MINS. DISCONNECTED #2 AND #3 CSD PER OPERATING MANUAL ABNORMAL PROC. REVIEWED AND EXECUTED SINGLE GENERATOR ABNORMAL PROC. RETURNED TO RDU. LANDED NORMALLY BELOW MAX LNDG WT.

Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.