Narrative:

During climb out from oak, #2 engine driven pump (B system) failed with no loss of fluid. Checklists were completed and we continued to sna. Approaching downwind at sna approximately 30 mins later hydraulic quantity in 'B' system decreased to zero. Accomplished 'B' system hydraulic failure checklist and diverted to lax so as to utilize longer runway.

Google
 

Original NASA ASRS Text

Title: A B737-400 LOSES ITS HYD PUMP IN 'B' SYS CLBING OUT OF OAK. DURING APCH INTO SNA THE SYS FLUID IS LOST. THE ACFT DIVERTS TO LAX.

Narrative: DURING CLBOUT FROM OAK, #2 ENG DRIVEN PUMP (B SYS) FAILED WITH NO LOSS OF FLUID. CHKLISTS WERE COMPLETED AND WE CONTINUED TO SNA. APCHING DOWNWIND AT SNA APPROX 30 MINS LATER HYD QUANTITY IN 'B' SYS DECREASED TO ZERO. ACCOMPLISHED 'B' SYS HYD FAILURE CHKLIST AND DIVERTED TO LAX SO AS TO UTILIZE LONGER RWY.

Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.