37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 399521 |
Time | |
Date | 199804 |
Day | Sat |
Local Time Of Day | 0601 To 1200 |
Place | |
Locale Reference | atc facility : pgs |
State Reference | AZ |
Altitude | msl bound lower : 31000 msl bound upper : 31000 |
Environment | |
Flight Conditions | VMC |
Light | Daylight |
Aircraft 1 | |
Controlling Facilities | artcc : zla |
Operator | common carrier : air carrier |
Make Model Name | B767 Undifferentiated or Other Model |
Operating Under FAR Part | Part 121 |
Navigation In Use | Other Other |
Flight Phase | cruise other other |
Flight Plan | IFR |
Person 1 | |
Affiliation | company : air carrier |
Function | flight crew : captain oversight : pic |
Qualification | pilot : atp |
ASRS Report | 399521 |
Person 2 | |
Affiliation | company : air carrier |
Function | flight crew : first officer |
Qualification | pilot : instrument pilot : commercial |
Events | |
Anomaly | aircraft equipment problem : critical other anomaly other |
Independent Detector | aircraft equipment other aircraft equipment : unspecified other flight crewa |
Resolutory Action | none taken : detected after the fact other |
Consequence | Other |
Supplementary | |
Primary Problem | Aircraft |
Air Traffic Incident | other |
Narrative:
On takeoff received left duct leak EICAS message. Turned left engine bleed valve off. In-flight conferred with dispatch and maintenance regarding troubleshooting problem and alternate plans to avoid icing conditions at destination. Maintenance corrective procedure of left pack off and left engine bleed on worked temporarily, but left duct leak light recurred. We then diverted to sfo which was clear.
Original NASA ASRS Text
Title: AN ACR B767 FLC EXPERIENCED A PNEUMATIC DUCT LEAK IN THE L AIR BLEED SYS. THE FLC SHUT OFF THE L ENG BLEED AND DIVERTED TO AN ARPT THAT HAD CLR WX.
Narrative: ON TKOF RECEIVED L DUCT LEAK EICAS MESSAGE. TURNED L ENG BLEED VALVE OFF. INFLT CONFERRED WITH DISPATCH AND MAINT REGARDING TROUBLESHOOTING PROB AND ALTERNATE PLANS TO AVOID ICING CONDITIONS AT DEST. MAINT CORRECTIVE PROC OF L PACK OFF AND L ENG BLEED ON WORKED TEMPORARILY, BUT L DUCT LEAK LIGHT RECURRED. WE THEN DIVERTED TO SFO WHICH WAS CLR.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.