37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 578567 |
Time | |
Date | 200304 |
Day | Tue |
Local Time Of Day | 1201 To 1800 |
Place | |
Locale Reference | airport : zzz.airport |
State Reference | US |
Altitude | agl single value : 0 |
Environment | |
Light | Daylight |
Aircraft 1 | |
Operator | common carrier : air carrier |
Make Model Name | B737-200 |
Operating Under FAR Part | Part 121 |
Flight Phase | ground : maintenance |
Person 1 | |
Affiliation | company : air carrier |
Function | maintenance : technician |
Qualification | technician : airframe technician : powerplant |
Experience | maintenance technician : 10 |
ASRS Report | 578567 |
Person 2 | |
Affiliation | company : air carrier |
Function | maintenance : lead technician |
Events | |
Anomaly | aircraft equipment problem : critical maintenance problem : improper documentation maintenance problem : improper maintenance non adherence : far non adherence : published procedure |
Resolutory Action | none taken : detected after the fact |
Consequence | other other Other |
Factors | |
Maintenance | contributing factor : schedule pressure performance deficiency : non compliance with legal requirements performance deficiency : logbook entry performance deficiency : installation performance deficiency : unqualified personnel |
Supplementary | |
Problem Areas | Company Aircraft Maintenance Human Performance |
Primary Problem | Maintenance Human Performance |
Narrative:
Arrived at gate X. Pilot reported #1 generator worked ok, but had no volt or frequency indication. All other generators and indications worked ok. I installed an overhead module P-5-13 electrical meters, battery and galley power. The cause of the event was because I did not check mpd 25 to determine the part was correct.
Original NASA ASRS Text
Title: A B737-200 WAS DISPATCHED IN NON COMPLIANCE WITH THE INCORRECT P5-13 ELECTRICAL INDICATION OVERHEAD PANEL INSTALLED.
Narrative: ARRIVED AT GATE X. PLT RPTED #1 GENERATOR WORKED OK, BUT HAD NO VOLT OR FREQ INDICATION. ALL OTHER GENERATORS AND INDICATIONS WORKED OK. I INSTALLED AN OVERHEAD MODULE P-5-13 ELECTRICAL METERS, BATTERY AND GALLEY PWR. THE CAUSE OF THE EVENT WAS BECAUSE I DID NOT CHK MPD 25 TO DETERMINE THE PART WAS CORRECT.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.