37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 657402 |
Time | |
Date | 200505 |
Local Time Of Day | 0601 To 1200 |
Place | |
Locale Reference | airport : zzz.airport |
State Reference | US |
Altitude | agl single value : 0 |
Aircraft 1 | |
Controlling Facilities | tracon : sct.tracon |
Operator | common carrier : air carrier |
Make Model Name | B757-200 |
Operating Under FAR Part | Part 121 |
Flight Phase | ground : parked ground : maintenance |
Flight Plan | IFR |
Person 1 | |
Affiliation | company : air carrier |
Qualification | technician : airframe technician : powerplant |
Experience | maintenance lead technician : 15 maintenance technician : 18 |
ASRS Report | 657402 |
Person 2 | |
Affiliation | company : air carrier |
Function | flight crew : captain oversight : pic |
Events | |
Anomaly | aircraft equipment problem : critical maintenance problem : improper maintenance non adherence : published procedure non adherence : far |
Independent Detector | aircraft equipment other aircraft equipment : lt hydraulic qty ind other flight crewa other flight crewb |
Resolutory Action | other |
Consequence | other |
Factors | |
Maintenance | contributing factor : schedule pressure performance deficiency : fault isolation performance deficiency : inspection performance deficiency : repair |
Supplementary | |
Problem Areas | Maintenance Human Performance Aircraft Environmental Factor |
Primary Problem | Maintenance Human Performance |
Narrative:
Aircraft X; gate called approximately XA00. Hydraulic leak at right main landing gear well. Found down lock actuator line dripping. Tightened line; lear checked good. Aircraft took off and returned to field (XB00). Left system hydraulic quantity low. Found line previously tightened had blown hole in side of line above fitting. Replaced line with temporary line and programmed for replacement. Aircraft landed approximately XE00.
Original NASA ASRS Text
Title: A B757-200 HAD R MAIN GEAR DOWN LOCK LINE TIGHTENED DUE TO LEAK. FLT RETURNED TO FIELD DUE TO L HYD SYS QUANTITY LOW. TIGHTENED LINE FOUND LEAKING FROM HOLD IN LINE. REPLACED LINE.
Narrative: ACFT X; GATE CALLED APPROX XA00. HYD LEAK AT R MAIN LNDG GEAR WELL. FOUND DOWN LOCK ACTUATOR LINE DRIPPING. TIGHTENED LINE; LEAR CHKED GOOD. ACFT TOOK OFF AND RETURNED TO FIELD (XB00). L SYS HYD QUANTITY LOW. FOUND LINE PREVIOUSLY TIGHTENED HAD BLOWN HOLE IN SIDE OF LINE ABOVE FITTING. REPLACED LINE WITH TEMPORARY LINE AND PROGRAMMED FOR REPLACEMENT. ACFT LANDED APPROX XE00.
Data retrieved from NASA's ASRS site as of January 2009 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.