37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 695455 |
Time | |
Date | 200604 |
Place | |
Locale Reference | airport : zzz.airport |
State Reference | US |
Altitude | agl single value : 0 |
Environment | |
Light | Night |
Aircraft 1 | |
Operator | common carrier : air carrier |
Make Model Name | B737-300 |
Operating Under FAR Part | Part 121 |
Flight Phase | ground : maintenance |
Person 1 | |
Affiliation | company : air carrier |
Function | maintenance : lead technician oversight : supervisor |
Qualification | technician : powerplant technician : airframe |
ASRS Report | 695455 |
Person 2 | |
Affiliation | company : air carrier |
Function | maintenance : technician |
Events | |
Anomaly | aircraft equipment problem : critical maintenance problem : improper maintenance maintenance problem : improper documentation non adherence : published procedure non adherence : far |
Independent Detector | other other : 1 |
Resolutory Action | none taken : detected after the fact |
Consequence | other other |
Factors | |
Maintenance | contributing factor : schedule pressure performance deficiency : non compliance with legal requirements performance deficiency : installation performance deficiency : logbook entry performance deficiency : testing |
Supplementary | |
Problem Areas | Maintenance Human Performance Environmental Factor Aircraft |
Primary Problem | Maintenance Human Performance |
Situations | |
Publication | Maint Manual |
Narrative:
On apr/xa/06 the #1 engine driven hydro pump was removed and replaced due to metal in the case drain filter. I overlooked the drain and flush of the hydro system as called out in the maintenance manual or change the case drain filter after the leak/operations check.
Original NASA ASRS Text
Title: A B737-300 #1 ENG DRIVEN HYD PUMP WAS REPLACED DUE TO METAL IN THE CASE DRAIN FILTER. AFTER PUMP REPLACED DRAIN AND FLUSH OF SYS PER MAINT MANUAL PROC NOT ACCOMPLISHED.
Narrative: ON APR/XA/06 THE #1 ENG DRIVEN HYDRO PUMP WAS REMOVED AND REPLACED DUE TO METAL IN THE CASE DRAIN FILTER. I OVERLOOKED THE DRAIN AND FLUSH OF THE HYDRO SYS AS CALLED OUT IN THE MAINT MANUAL OR CHANGE THE CASE DRAIN FILTER AFTER THE LEAK/OPS CHK.