37000 Feet | Browse and search NASA's Aviation Safety Reporting System |
|
Attributes | |
ACN | 310847 |
Time | |
Date | 199507 |
Day | Sun |
Local Time Of Day | 0601 To 1200 |
Place | |
Locale Reference | airport : stl |
State Reference | MO |
Altitude | msl bound lower : 20000 msl bound upper : 20000 |
Environment | |
Flight Conditions | VMC |
Light | Daylight |
Aircraft 1 | |
Controlling Facilities | artcc : zkc tower : lax |
Operator | common carrier : air carrier |
Make Model Name | Commercial Fixed Wing |
Operating Under FAR Part | Part 121 |
Flight Phase | other other |
Route In Use | departure other departure sid : sid |
Flight Plan | IFR |
Person 1 | |
Affiliation | company : air carrier |
Function | flight crew : captain oversight : pic |
Qualification | pilot : flight engineer pilot : cfi pilot : atp |
Experience | flight time last 90 days : 150 flight time total : 12000 flight time type : 1000 |
ASRS Report | 310847 |
Person 2 | |
Affiliation | company : air carrier |
Function | flight crew : first officer |
Qualification | pilot : commercial pilot : instrument |
Events | |
Anomaly | aircraft equipment problem : critical other anomaly other |
Independent Detector | aircraft equipment other aircraft equipment : unspecified other flight crewa |
Resolutory Action | flight crew : declared emergency none taken : unable other |
Consequence | Other |
Narrative:
During climb, observed right constant speed drive outlet temperature higher than normal and rising. When temperature reached caution range (above 146 degrees C) started APU and transferred right AC bus to APU generator. Shortly thereafter, APU generator failed and AC x-tie locked out. Almost simultaneously, constant speed drive outlet temperature reached red line (163 degrees C) requiring constant speed drive disconnect. When constant speed drive disconnected, lost power to right AC bus. Declared emergency due to possible short on right AC bus. Returned stl, landed approximately 140000 pounds (maximum landing weight 130000 pounds). Landing normal. Maintenance found constant speed drive oversvced, APU generator failed for unknown reason. AC x-tie lockout reset on ground. AC bus ok. Placarded APU generator inoperative, reoriginated flight. Constant speed drive operation normal remainder of flight.
Original NASA ASRS Text
Title: RETURN LAND WITH AN OVERWT LNDG.
Narrative: DURING CLB, OBSERVED R CONSTANT SPD DRIVE OUTLET TEMP HIGHER THAN NORMAL AND RISING. WHEN TEMP REACHED CAUTION RANGE (ABOVE 146 DEGS C) STARTED APU AND TRANSFERRED R AC BUS TO APU GENERATOR. SHORTLY THEREAFTER, APU GENERATOR FAILED AND AC X-TIE LOCKED OUT. ALMOST SIMULTANEOUSLY, CONSTANT SPD DRIVE OUTLET TEMP REACHED RED LINE (163 DEGS C) REQUIRING CONSTANT SPD DRIVE DISCONNECT. WHEN CONSTANT SPD DRIVE DISCONNECTED, LOST PWR TO R AC BUS. DECLARED EMER DUE TO POSSIBLE SHORT ON R AC BUS. RETURNED STL, LANDED APPROX 140000 LBS (MAX LNDG WT 130000 LBS). LNDG NORMAL. MAINT FOUND CONSTANT SPD DRIVE OVERSVCED, APU GENERATOR FAILED FOR UNKNOWN REASON. AC X-TIE LOCKOUT RESET ON GND. AC BUS OK. PLACARDED APU GENERATOR INOP, REORIGINATED FLT. CONSTANT SPD DRIVE OP NORMAL REMAINDER OF FLT.
Data retrieved from NASA's ASRS site as of July 2007 and automatically converted to unabbreviated mixed upper/lowercase text. This report is for informational purposes with no guarantee of accuracy. See NASA's ASRS site for official report.